Panel Information
| Barcode | 6442-PY-13-1F |
| Panel Number | PY-13-1F |
| Site | St Johns (#6442) |
| Plot | — |
| Position | PY |
| Floor | FF |
| Block | SE |
| Length | 2398 mm |
| CDT File | Z:\6442_St Johns_-BL SE_PL_-FF_PY\6442_St Johns_-BL SE_PL_-89-2665\FRAMEPY-13-1F.CDT |
| Status | Complete |
| Created | 13/07/2026 15:51:03 |
| Completed | 14/07/2026 11:58:33 |
Station Timeline
Framing Station
Printed: 15:51:03
Insulation Boarding
Arrived: 07:34:04
· Left: 08:07:54
· 2030s
Nailing Bridge
Arrived: 08:07:54
· Left: 08:25:12
· 1038s
Paper Application
Arrived: 08:25:12
· Left: 08:26:10
· 57s
Panel Flipping
Arrived: 08:26:10
· Left: 11:58:33
· 12742s
Insulation Filling
Not yet reached
OSB Glue Application
Not yet reached
Paper Application 2
Not yet reached
Exit Line to Windows
Not yet reached
All Scan Events
4 total
| Time | Station | Scanner | Barcode | Type |
|---|---|---|---|---|
| 07:34:04 | Insulation Boarding | Scanner 1 | 6442-PY-13-1F | Entry |
| 08:07:54 | Nailing Bridge | Scanner 2 | 6442-PY-13-1F | Entry |
| 08:25:12 | Paper Application | Scanner 3 | 6442-PY-13-1F | Entry |
| 08:26:10 | Panel Flipping | Scanner 4 | 6442-PY-13-1F | Entry |